{"id":3350,"date":"2026-02-02T22:01:36","date_gmt":"2026-02-02T14:01:36","guid":{"rendered":"https:\/\/airscan.org\/?p=3350"},"modified":"2026-02-09T00:15:31","modified_gmt":"2026-02-08T16:15:31","slug":"de-lair-pur-dans-les-ecoles-3-ans-de-surveillance-de-la-qualite-de-lair-dans-les-ecoles-belges","status":"publish","type":"post","link":"https:\/\/airscan.org\/fr\/insights\/indoor-monitoring\/clean-air-for-schools-3-years-of-air-quality-monitoring-in-belgian-schools\/","title":{"rendered":"De l&#039;air pur dans les \u00e9coles : 3 ans de surveillance de la qualit\u00e9 de l&#039;air dans les \u00e9coles belges"},"content":{"rendered":"<p><strong><a href=\"https:\/\/cleanairforschools.be\/\" target=\"_blank\" rel=\"noopener\">De l'air pur pour les \u00e9coles<\/a><\/strong> est une collaboration entre Airscan et <strong><a href=\"https:\/\/www.belfius.be\" target=\"_blank\" rel=\"noopener\">Belfius<\/a><\/strong> Lanc\u00e9e en 2020, cette initiative vise \u00e0 aider les \u00e9coles belges \u00e0 am\u00e9liorer la qualit\u00e9 de l&#039;air int\u00e9rieur. Pendant trois ans, des donn\u00e9es environnementales ont \u00e9t\u00e9 collect\u00e9es et analys\u00e9es dans 72 \u00e9coles \u00e0 travers la Belgique. Le suivi s&#039;est concentr\u00e9 sur trois groupes de polluants\u00a0: le dioxyde de carbone (CO\u2082), les particules fines (PM) et les compos\u00e9s organiques volatils (COV).<\/p>\n\n\n\n<p>Le programme a \u00e9t\u00e9 con\u00e7u pour fournir aux \u00e9coles les moyens techniques, humains et financiers n\u00e9cessaires pour identifier les probl\u00e8mes de qualit\u00e9 de l&#039;air et r\u00e9duire les risques sanitaires, tout en limitant la consommation d&#039;\u00e9nergie inutile.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pourquoi la qualit\u00e9 de l&#039;air int\u00e9rieur dans les \u00e9coles est importante<\/h3>\n\n\n\n<p>Les enfants passent environ un tiers de leur journ\u00e9e \u00e0 l&#039;int\u00e9rieur, dont pr\u00e8s de 70 % en classe. Compar\u00e9s aux adultes, ils sont plus vuln\u00e9rables \u00e0 une mauvaise qualit\u00e9 de l&#039;air int\u00e9rieur en raison de leurs organes immatures, de leur capacit\u00e9 pulmonaire r\u00e9duite et de leur fr\u00e9quence respiratoire plus \u00e9lev\u00e9e. Par cons\u00e9quent, la d\u00e9gradation de l&#039;environnement int\u00e9rieur peut nuire \u00e0 leur sant\u00e9 respiratoire et cardiovasculaire, ainsi qu&#039;\u00e0 leur concentration, leurs r\u00e9sultats scolaires et leur comportement.<\/p>\n\n\n\n<p>Comme ces expositions se produisent quotidiennement et sur de longues p\u00e9riodes, m\u00eame des niveaux de pollution mod\u00e9r\u00e9s mais persistants peuvent avoir des effets cumulatifs.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Justification du choix et de la mesure des polluants<\/h3>\n\n\n\n<p>La qualit\u00e9 de l&#039;air int\u00e9rieur englobe un large \u00e9ventail de param\u00e8tres. Lors de la conception du projet, Airscan a d\u00e9lib\u00e9r\u00e9ment limit\u00e9 son champ d&#039;application \u00e0 trois groupes de polluants \u00e0 la fois fr\u00e9quents dans les environnements scolaires et \u00e9troitement li\u00e9s \u00e0 la ventilation et au fonctionnement des b\u00e2timents.<\/p>\n\n\n\n<p>Le dioxyde de carbone est produit naturellement par la respiration. Bien qu&#039;il ne soit pas toxique aux concentrations habituelles \u00e0 l&#039;int\u00e9rieur des b\u00e2timents, il constitue un indicateur fiable de l&#039;efficacit\u00e9 de la ventilation. Des niveaux \u00e9lev\u00e9s de CO\u2082 indiquent un apport d&#039;air frais insuffisant et, lorsqu&#039;il s&#039;accumule dans des espaces confin\u00e9s, sont associ\u00e9s \u00e0 la fatigue, \u00e0 une baisse des performances cognitives et, dans certains cas, \u00e0 des naus\u00e9es.<\/p>\n\n\n\n<p>Les particules fines pr\u00e9sentes dans les \u00e9coles proviennent de sources multiples, notamment l&#039;utilisation de la craie, la d\u00e9gradation des mat\u00e9riaux de construction, le mat\u00e9riel artistique et la remise en suspension des particules d\u00e9pos\u00e9es par les mouvements des occupants ou la circulation de l&#039;air. Les particules fines sont particuli\u00e8rement pr\u00e9occupantes car elles peuvent p\u00e9n\u00e9trer profond\u00e9ment dans les poumons, franchir les barri\u00e8res physiologiques et accro\u00eetre le risque d&#039;infections et de maladies respiratoires.<\/p>\n\n\n\n<p>Il est plus difficile d&#039;attribuer les compos\u00e9s organiques volatils \u00e0 des sources uniques. Ils sont couramment \u00e9mis par les produits de nettoyage, les parfums, les colles et certaines peintures. Ces compos\u00e9s sont chimiquement r\u00e9actifs et sont associ\u00e9s \u00e0 des irritations, des inconforts, une baisse de la concentration et divers effets n\u00e9fastes sur la sant\u00e9.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Seuil et cadre de r\u00e9f\u00e9rence<\/h3>\n\n\n\n<p>Les seuils de pollution ont \u00e9t\u00e9 d\u00e9finis \u00e0 partir de r\u00e9f\u00e9rences sanitaires et r\u00e9glementaires \u00e9tablies. Pour le CO\u2082, une limite de 900 ppm a \u00e9t\u00e9 appliqu\u00e9e, conform\u00e9ment aux recommandations de [r\u00e9f\u00e9rence manquante]. <strong>SPF Sant\u00e9 Publique, S\u00e9curit\u00e9 de la Cha\u00eene Alimentaire et Environnement<\/strong>. Concernant les PM2,5, la valeur guide de 5 \u00b5g\/m\u00b3 publi\u00e9e en 2021 par la <strong><a href=\"https:\/\/www.who.int\" target=\"_blank\" rel=\"noopener\">Organisation mondiale de la sant\u00e9<\/a><\/strong> Les concentrations de COV ont \u00e9t\u00e9 \u00e9valu\u00e9es par rapport \u00e0 un seuil de 79,6 ppb (300 \u00b5g\/m\u00b3), d\u00e9riv\u00e9 de la norme Binnenmilieubesluit \u00e9mise par la <strong>Hoge Gezondheidsraad<\/strong>.<\/p>\n\n\n\n<p>Ces valeurs de r\u00e9f\u00e9rence ont servi de base \u00e0 toutes les \u00e9valuations comparatives r\u00e9alis\u00e9es au cours du projet.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"907\" height=\"176\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-1-2.avif\" alt=\"\" class=\"wp-image-3356\" srcset=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-1-2.avif 907w, https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-1-2-768x149.jpg 768w\" sizes=\"(max-width: 907px) 100vw, 907px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Processus de mesure et suivi<\/h3>\n\n\n\n<p>Dans chaque \u00e9cole participante, les techniciens d&#039;Airscan ont install\u00e9 trois dispositifs de surveillance int\u00e9rieure dans des salles de classe s\u00e9lectionn\u00e9es. Apr\u00e8s un mois de collecte de donn\u00e9es, un diagnostic initial a \u00e9t\u00e9 r\u00e9alis\u00e9 afin d&#039;\u00e9tablir les conditions de r\u00e9f\u00e9rence. Les r\u00e9sultats, accompagn\u00e9s de recommandations pratiques, ont \u00e9t\u00e9 pr\u00e9sent\u00e9s aux directeurs d&#039;\u00e9cole, aux enseignants ou aux conseils de pr\u00e9vention.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"729\" height=\"253\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-2.avif\" alt=\"\" class=\"wp-image-3355\"\/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"778\" height=\"231\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-3-2.avif\" alt=\"\" class=\"wp-image-3354\" srcset=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-3-2.avif 778w, https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-3-2-768x228.jpg 768w\" sizes=\"(max-width: 778px) 100vw, 778px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>Ces recommandations portaient notamment sur l&#039;am\u00e9lioration des pratiques de renouvellement d&#039;air, l&#039;ajustement des calendriers de nettoyage et l&#039;utilisation des produits. Une \u00e9valuation finale a \u00e9t\u00e9 men\u00e9e apr\u00e8s six mois afin de d\u00e9terminer si les mesures propos\u00e9es avaient permis d&#039;obtenir des am\u00e9liorations tangibles.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Concentrations moyennes apr\u00e8s six mois<\/h3>\n\n\n\n<p>\u00c0 la fin de la p\u00e9riode de surveillance de six mois, la plupart des \u00e9coles ont enregistr\u00e9 des concentrations moyennes inf\u00e9rieures aux seuils recommand\u00e9s pour le dioxyde de carbone et les compos\u00e9s organiques volatils. Soixante-sept pour cent des \u00e9coles respectaient le seuil de CO\u2082, tandis que 551 \u00e9coles (TP3T) respectaient le seuil de COV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"925\" height=\"131\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-2-2.avif\" alt=\"\" class=\"wp-image-3353\" srcset=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-2-2.avif 925w, https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Table-2-2-768x109.jpg 768w\" sizes=\"(max-width: 925px) 100vw, 925px\" \/><\/figure>\n\n\n\n<p>Les particules fines ont pr\u00e9sent\u00e9 un profil diff\u00e9rent. Seules 161 \u00e9coles (TP3T) ont enregistr\u00e9 des concentrations moyennes de PM2,5 inf\u00e9rieures aux recommandations de l&#039;OMS, ce qui indique que les particules fines constituent un probl\u00e8me plus persistant dans les environnements scolaires que le CO\u2082 ou les COV.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Strat\u00e9gie de ventilation et effets observ\u00e9s<\/h3>\n\n\n\n<p>Le recours exclusif \u00e0 la ventilation naturelle s&#039;av\u00e9rait souvent insuffisant pour maintenir les concentrations de CO\u2082 en dessous des limites recommand\u00e9es, notamment dans les b\u00e2timents anciens disposant de peu de fen\u00eatres ouvrantes ou dans les petites salles de classe \u00e0 forte occupation. La ventilation naturelle peut \u00e9galement introduire des polluants ext\u00e9rieurs dans les espaces int\u00e9rieurs, ce qui est particuli\u00e8rement pertinent pour les particules fines.<\/p>\n\n\n\n<p>Les salles de classe \u00e9quip\u00e9es de syst\u00e8mes de ventilation m\u00e9canique ont pr\u00e9sent\u00e9 des am\u00e9liorations constantes pour les trois groupes de polluants. Dans les 72 \u00e9coles \u00e9tudi\u00e9es, l&#039;installation d&#039;une ventilation m\u00e9canique a \u00e9t\u00e9 associ\u00e9e \u00e0 des r\u00e9ductions moyennes de 461 Tp\/kg pour les COV, de 251 Tp\/kg pour les particules fines et de 191 Tp\/kg pour le dioxyde de carbone.<\/p>\n\n\n\n<p>Dans une \u00e9cole, un syst\u00e8me de ventilation m\u00e9canique install\u00e9 deux mois apr\u00e8s le d\u00e9but de la campagne de mesure a r\u00e9duit les concentrations moyennes de CO\u2082 de 1 288 ppm \u00e0 811 ppm, ainsi qu&#039;une r\u00e9duction de 25% des particules et de 50% des COV.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"858\" height=\"591\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-4-2.avif\" alt=\"\" class=\"wp-image-3352\" style=\"aspect-ratio:1.4517821192616327;width:414px;height:auto\" srcset=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-4-2.avif 858w, https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-4-2-768x529.jpg 768w\" sizes=\"(max-width: 858px) 100vw, 858px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Limitations de maintenance et du syst\u00e8me<\/h3>\n\n\n\n<p>Les r\u00e9sultats soulignent \u00e9galement que les syst\u00e8mes de ventilation n\u00e9cessitent un entretien et un contr\u00f4le appropri\u00e9s. Des filtres obstru\u00e9s et des conduits contamin\u00e9s peuvent restreindre le flux d&#039;air et redistribuer les polluants, tandis que des syst\u00e8mes mal con\u00e7us peuvent ne pas desservir toutes les zones occup\u00e9es ou ne pas g\u00e9rer correctement l&#039;humidit\u00e9 et la temp\u00e9rature.<\/p>\n\n\n\n<p>L&#039;efficacit\u00e9 de la ventilation d\u00e9pend donc non seulement de l&#039;installation, mais aussi de son fonctionnement et de sa surveillance \u00e0 long terme.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Mesures d&#039;att\u00e9nuation cibl\u00e9es \u00e0 l&#039;aide de purificateurs d&#039;air<\/h3>\n\n\n\n<p>L\u00e0 o\u00f9 la ventilation m\u00e9canique \u00e9tait impossible, d&#039;autres solutions ont \u00e9t\u00e9 envisag\u00e9es. Dans une \u00e9cole situ\u00e9e \u00e0 proximit\u00e9 d&#039;un atelier de menuiserie, les concentrations \u00e9lev\u00e9es de particules fines ont \u00e9t\u00e9 trait\u00e9es par l&#039;installation d&#039;un purificateur d&#039;air vers la fin de la campagne.<\/p>\n\n\n\n<p>Suite \u00e0 l&#039;installation du dispositif, les concentrations de PM2,5 dans la salle de classe concern\u00e9e ont diminu\u00e9 de plus de 501 TP3T. Ce cas illustre l&#039;influence des infrastructures du b\u00e2timent sur la qualit\u00e9 de l&#039;air int\u00e9rieur, depuis l&#039;ouverture des fen\u00eatres jusqu&#039;au confinement des \u00e9missions provenant d&#039;espaces sp\u00e9cifiques.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"998\" height=\"846\" src=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-5-2.avif\" alt=\"\" class=\"wp-image-3351\" style=\"aspect-ratio:1.1796691396709829;width:394px;height:auto\" srcset=\"https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-5-2.avif 998w, https:\/\/airscan.org\/wp-content\/uploads\/2026\/02\/Figure-5-2-768x651.jpg 768w\" sizes=\"(max-width: 998px) 100vw, 998px\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Principales observations tir\u00e9es de trois ann\u00e9es de suivi<\/h3>\n\n\n\n<p>Les donn\u00e9es recueillies pendant trois ans par Beats for Planet indiquent que les particules fines constituent une pr\u00e9occupation plus persistante dans les \u00e9coles belges que le dioxyde de carbone ou les compos\u00e9s organiques volatils. Les syst\u00e8mes de ventilation m\u00e9canique, lorsqu&#039;ils sont correctement con\u00e7us et entretenus, am\u00e9liorent significativement la qualit\u00e9 de l&#039;air int\u00e9rieur pour tous les polluants mesur\u00e9s. Les purificateurs d&#039;air peuvent constituer une mesure compl\u00e9mentaire efficace pour r\u00e9duire les particules fines dans les salles de classe expos\u00e9es \u00e0 des sources localis\u00e9es.<\/p>","protected":false},"excerpt":{"rendered":"<p>Trois ann\u00e9es de suivi dans 72 \u00e9coles belges montrent que les particules fines restent le principal probl\u00e8me de qualit\u00e9 de l&#039;air int\u00e9rieur, tandis que la ventilation m\u00e9canique et la purification cibl\u00e9e de l&#039;air apportent des am\u00e9liorations mesurables.<\/p>","protected":false},"author":8,"featured_media":3357,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[5],"tags":[],"class_list":["post-3350","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-indoor-monitoring"],"acf":[],"_links":{"self":[{"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/posts\/3350","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/users\/8"}],"replies":[{"embeddable":true,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/comments?post=3350"}],"version-history":[{"count":1,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/posts\/3350\/revisions"}],"predecessor-version":[{"id":3358,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/posts\/3350\/revisions\/3358"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/media\/3357"}],"wp:attachment":[{"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/media?parent=3350"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/categories?post=3350"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/airscan.org\/fr\/wp-json\/wp\/v2\/tags?post=3350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}