ICOP 2010 Indoor Air Quality Testing Service

Airscan delivers formal workplace air quality assessment covering the full physical, chemical and biological scope that Malaysian occupational safety law requires of every commercial workplace.

Assessed by:

Syida Nazri, Head of IAQ Department

DOSH-registered IAQ Assessor, PhD Candidate, Head of IAQ at Airscan Malaysia.

ICOP 2010 IAQ Assessment

The Industry Code of Practice on Indoor Air Quality 2010 (ICOP IAQ 2010), gazetted by the Department of Occupational Safety and Health, sets acceptable thresholds for temperature, humidity, air movement, chemical contaminants and microbiology in any workspace served by mechanical ventilation. ICOP places ongoing duties on employers: maintain the air, document the maintenance, and produce evidence of compliance when DOSH requests it. 

A formal IAQ assessment by a DOSH-registered Assessor is the instrument that produces that evidence. Airscan Malaysia delivers formal IAQ assessments based on ICOP IAQ 2010, conducted by our in-house registered IAQ Assessor across the full scope of parameters the standard requires.

When is a formal IAQ assessment required?

Persistent health complaints

Occupant complaints about air quality, temperature or persistent odours that internal troubleshooting can't resolve.

DOSH directive

A formal directive from DOSH following a workplace audit or an escalated complaint requires assessment by a registered IAQ Assessor.

Post-renovation or fit-out

New laminates, adhesives & wood off-gas formaldehyde & VOCs months after installation, making assessment the practical standard before re-occupation.

MVAC installation or major modification

New or significantly modified ventilation systems change the air delivery profile of a space - which warrants verification against ICOP's physical & chemical limits.

Baseline compliance

A building with no prior formal assessment has no documented evidence of compliance.

Leasing competitiveness

Multinational tenants and institutional occupants increasingly require verified IAQ data during pre-lease evaluation.

Our testing timeline

Scoping & complaint review

Review occupant complaint history, building layout, ventilation system configuration & operational context to define the assessment scope & sampling strategy.

Walkthrough inspection

On-site visual inspection of ductwork, cooling coils, drain pans, AHUs, filtration systems & potential contamination sources.

Sampling plan

Sampling points are determined by floor area using ICOP's prescribed density guidelines, designed to capture representative conditions across all zones.

Onsite measurement

Physical & chemical parameters are measured simultaneously over an 8-hour period under normal occupancy.

Biological sampling & lab analysis

Air samples for total bacterial count and total fungal count are collected onsite and submitted for analysis to a laboratory accredited by Department of Standards Malaysia.

Report & corrective recommendations

Comprehensive report covering compliance status per parameter across sampling points, identified pollution sources, MVAC system evaluation, and prioritised corrective action.

How the assessment works

Methods & instruments

Full documentation sampling methods, equipment used and calibration status.

Pollution sources

Contamination sources identified through inspection and measurement data, with location and likely contributors.

Results per point

Tabulated measurments for each parameter at each sampling location.

MVAC system evaluation

Condition assessment of ventilation system, covering identified deficiencies in maintenance, filtration and airflow delivery.

Occupant complaint correlation

Documentation of occupant complaints + correlation to measured conditions and identified contamination sources.

Compliance status

Pass or fail determination per parameter at each sampling point.

Corrective actions

Prioritised recommendations for bringing non-compliant parameters within acceptable limits, with practical guidance on implementation sequence.

ICOP IAQ 2010 assessments cover ten parameters across three categories, each measured against DOSH’s published acceptable limits.

Physical

--- Air temperature

--- Relative humidity

--- Air movement

Biological

--- Total bacterial count

--- Total fungal count

Chemical

--- Carbon monoxide (CO)

--- Formaldehyde (CH₂O)

--- Ozone (O₃)

--- Respirable particulates (PM₁₀)

--- Total volatile organic compounds (TVOC)

--- Carbon dioxide (CO₂)

Learn more about IAQ in Malaysia

How Sick Building Syndrome Gets Tested and Assessed in Malaysia

Indoor office environment in Malaysia

What El Niño means for indoor environments in Malaysia

Testing the air quality in an office

Symptoms of poor indoor air quality in Malaysian offices

Indoor air quality in a standard office

OSHA and ICOP 2010: A Look at the Indoor Air Quality Laws in Malaysia

FAQ

A formal ICOP assessment must be conducted by a DOSH-registered IAQ Assessor, follows ICOP’s prescribed sampling density per floor area, measures all parameters over an 8-hour time-weighted average under normal occupancy, and produces a report that carries legal standing as evidence of compliance under OSHA 1994.

A generic IAQ test, whether performed with handheld instruments, by an unregistered contractor, or using a different sampling methodology, may produce useful data, but the resulting report has no standing if DOSH requests evidence of compliance or if the assessment is produced in response to a directive. 

A breach of general duty under OSHA 1994 can carry a fine of up to RM500,000, imprisonment of up to 2 years, or both. Failure to comply with a Notice of Improvement or Notice of Prohibition issued by DOSH reaches the same RM500,000 ceiling, and continued non-compliance after a notice incurs a daily penalty of RM2,000. The OSHA Amendment 2022 introduced personal liability for directors and managers, which means the consequences of a serious IAQ failure extend beyond the company to the individuals responsible for the workplace.

An OSH Coordinator must be appointed if the workplace has 5 or more employees and does not employ a dedicated Safety and Health Officer. A documented complaint procedure must exist in writing and be accessible to all staff. MVAC systems must be inspected and maintained at least every six months, with records kept as evidence. All employees must receive training on ICOP’s contents and how to recognise signs of poor ventilation at least once every two years. These 4 duties apply independently of whether the air sits within acceptable range on any given day, and DOSH expects to find documentation for each of them during an audit.

Any building or enclosed area served by a mechanical ventilating and air conditioning system, including air-cooled split units. Following the OSHA Amendment 2022, every commercial workplace in Malaysia falls within the Act’s enforcement scope. Domestic buildings constructed, used or intended for habitation are excluded, as are industrial premises covered by separate regulations under the Factories and Machinery Act.

The assessment report identifies which parameters exceeded acceptable limits, where the exceedances occurred, and what’s likely causing them. Corrective actions are prioritised based on severity, with practical guidance on implementation sequence. For buildings where conditions fluctuate between periodic assessments, continuous indoor air quality monitoring provides (among a host of important applications) real-time visibility into parameter trends and alerts building management when conditions drift outside the acceptable range.

Only a person registered with the Director General of DOSH as an Indoor Air Quality Assessor. Registration requires specific qualifications, experience, and training, and must be renewed periodically. Self-certification has no legal standing, and an assessment signed by anyone without DOSH registration will not satisfy ICOP’s requirements in the event of an audit, directive or legal proceeding. Find out more about, or connect with Ts. Syida Nazri, Airscan’s IAQ Assessor. 

Assessment reports must be retained for thirty years. Complaint logs, investigation reports, training records, and MVAC maintenance records must be kept for five years. These retention periods are prescribed by ICOP and apply regardless of whether the building changes ownership or management during the retention window.